24시간 혈압측정기

[24시간혈압측정시스템]24시간 실생활 혈압측정을 통한 정밀 혈압 변화도 분석과 평가가 가능한 혈압측정시스템, 24hour Blood Pressure,Ambulatory Blood Pressure Recorder, Mobile O Graph

medicaldevice 2014. 8. 29. 12:57

[24시간혈압측정시스템]24시간 실생활 혈압측정을 통한 정밀 혈압 변화도 분석과 평가가 가능한 혈압측정시스템, 24hour Blood Pressure,Ambulatory Blood Pressure Recorder, Mobile O Graph

 

 

24 Hour ABPM and Arterial Pulse Wave Analysis

 

24시간 혈압측정계
24시간 실시간혈압측정 시스템

 

Key Cardiovascular Hemodynamaics Now Easily Integrarted With Your Practice

24시간 혈압측정시스템
24시간 혈압측정기

 

An innovative ​Hypertension Management Concept with the option of PWA

- 24/48 hour ambulatory measurement or periphetal bolld pressure

- Mean arterial pressure

- Early morning rise analysis

 

24시간 혈압측정시스템
수면중 혈압측정시스템

 

Optional : Pulse Wave Analysis

- Central aortic blood pressure

- Cardiac output

- Arterial stiffness measured in augmentation index (AIx) and reflection coefficient​

- A huge leap forward!​

 

 

Pulse Wave Analysis and 24 hour ABPM

- Capture traditional 24 hour ABPM data puls wave velocity(PWM) profile

- Requires no additional staffing or administration

- Silmple operation and implementation

 

24시간 혈압측정계
실시간 혈압측정시스템

 

Recent advances in outpatient BP monitoring technology have made it possible to now capture the arterial pulse wave velocity(PWV) profile, a key variable closely reflective of large​ vessel vascular elasticity.

 

For most hypertensives, the most critical change in vascular stiffness takes place in the aorta where loss of elasticity results in higher central aortic pressures/cardic afterload and over time, diminished cornary perfusion.

 

The end result is an increase in cardiovascular injury, chronic morbidity and mortality.

 

By capturing and analyzing the patient's aortic PWV profile, clinicians can now have a direct insight into the extent of large vessel hypertensive injury.

 

Increased cardiac afterload results in long term injury to cornary vessels

 

It provides both classic 24-hour ABPM data and a highly accurate aortic PWV profile. This new combined capability is a vast improvement in diagnostic accuracy and the assement of effective BP treatment.

 

A stiffer aortic wall results in a stronger reflection of the systolic pulse wave creating higher peak aortic pressure.

It transfers the pressure curve data wirelessly to the HMS CS analysis software which produces an accurate assessment of both the patient's BP management and total vascular condition

 

24시간 혈압측정계
24시간 실시간혈압측정시스템

 

 A new benchmark and opens new perspectives for clinics an MDs.

 

▷ Unsurpassed patient comfort and acceptance by using Auto-Feedback-Logic AFL

- Significantly better night sleep for the patient through individualized inflation

- Gentle and fast measurement of blood pressure

- Maximum comfort thanks to correct-sized cuffs with ease of application

 

▷ Easy handling in everyday office routine

- Wireless and rapid read in / read out between the monitor and the PC

- Percise graphics, early morning rise analysis, comparison profiles

- Documentation and storage ot all ambulatory and self-measured blood pressure data in the Hyper-tension Management Siftware (HSM) CS with interface to clinical information systems

 

▷ Pulse Wave Analysis - Optional to your 24h ABPM

- AIx and reflection coefficient - two strong cardio-vascular biomarkets for risk stratification and therapy management for risk stratification and therapy management for hypertensive pateints.

- Easy, fast, delegable methodology within the ABPM routine

- Percise analysis fo hemodynamics, blood pressure and arterial stiffness

 

24시간혈압측정계
실시간 혈압측정시스템

 

 

Pulse wave velocity analysis is recommended by the European Socity for Hypertension(ESH) for the following conditions

- Isolated systolic

- Aortic insurfficiency

- Hyperthyridism

- Evaluation fo anti-hypertensive therapy in relation to arterial elasticity

- Typical HMS CS display of Pulse Wave Velocity Profile

24시간 혈압측정시스템
24시간 혈압측정기, Mobil O Graph

 

Unlike other ABPM system, It now offers

- A recording to the brachial pulse wave velocity profile from which to create

- A mathematical derivation to the aortic pulse wave velocity profile

- Graphical and tabular presentation of BP and Pulse wave profiles

 

Software Program

▷ BP measurementPC program

24시간혈압측정시스템
실시간혈압측정 PC 프로그램

 

24시간혈압측정시스템
24시간혈압측정결과정밀분석

 

▷ 24hr measurement

 

24시간혈압측정시스템
실시간혈압변화도 분석 그래프

 

Night time Blood Pressure Measurement

 

24시간 혈압측정시스템
수면중 혈압변화도 분석

 

 

Report​ Features

BP measurement

- Aggregated and organized BP rerading

- Mean, median std. deviation reports

- Circadian variability reports

 

24시간혈압측정계 결과지
실시간혈압측정 결과 그래프 분석 결과지

 

 

Pulse Wave Velocity

- Simple graphical disply

- Longitudinal analysis to assess the effectiveness of therapy over time​

 

24시간혈압측정계
실시간혈압측정시스템

 

 

 Specification

 

24시간혈압분석계
실시간혈압분석시스템

 

Measurement range : Systolic (SYS) 60 ~ 290 mmHg / Diastolic (DIA) : 30 - 195 mmHg

Accuracy : ± 3 mmHg

Pressure range : 0 to 300 mmHg

Measurement method : Oscillometric

Mesurement protocols

- 4 freely editable day / night intervals

- Measurements per hour : 1,2,4,5,6,10,15,20 or 30

- Optional : automatic transfer of Blood Pressure values via GSM

Memory : 300 measurements

Battery capacity : > 300 measurements

Operating temperature range : ​+ 10 ℃ to + 40 ℃

Operating air humidity range : 15% to 90%

Storage conditions : - 20 ℃​ to + 50 ℃ temp and 15% to 90% humidity

Dimensions : 128 X 75 X 30 mm

Weight : Approx. 240g including batteries

Power supply : 2 IEM rechangeable Ni-MH batteries (1,2 V and min. 2100 mAh)

Interfaces : Serial port(cable) compatible for USB Emulation / Infrared / Bluetooth(Class 1/100m)

PWA option : PWA is extendable through license dongles (100, 300, 1000 and unlimited)

 

24시간혈압분석계
실시간혈압분석시스템

 

Korea Sales HQ

Medical Device Korea

TEL : 02 553 0923

 

www.medicaldevice.kr

엠디케이(MDK)